Electric Pump: Difference between revisions
m (Reverted edits by Humut (talk) to last revision by Bigbass1997) |
No edit summary |
||
Line 1: | Line 1: | ||
[[Category:GT_Covers]] |
[[Category:GT_Covers]] |
||
The Electric Pump is a component used in the crafting of several [http://ftb.gamepedia.com/GregTech_5 GregTech 5] electric machines, |
The Electric Pump is a component used in the crafting of several [http://ftb.gamepedia.com/GregTech_5 GregTech 5] electric machines, but more importantly also functions as a [[:Category:GT_Covers| cover]] that can be used to automate fluid extraction and insertion. A [[Crowbar]] can be used to remove the Electric Pump from the machine or pipe that it is attached to. When it is attached to a machine, it will require power. Each tier of the Electric Pump has a different speed; every tick it will attempt to move fluid, if it succeeds it will consume 1 EU per 10L of fluid. If the pump is attached to a pipe however, it is not capable of consuming power, so it still functions just the same, but does not require power. |
||
== Modes == |
== Modes == |
||
The Electric Pump has several different operating modes. The active mode can be switched using a [[Screwdriver]]. |
The Electric Pump has several different operating modes. The active mode can be switched using a [[Screwdriver]]. |
||
{| class="wikitable" |
|||
TODO: Add modes table. |
|||
! Mode |
|||
! Description |
|||
|- |
|||
| Export |
|||
| Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
|||
|- |
|||
| Import |
|||
| Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
|||
|- |
|||
| Export (conditional) |
|||
| If allowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
|||
|- |
|||
| Import (conditional) |
|||
| If allowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
|||
|- |
|||
| Export (invert cond) |
|||
| If disallowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
|||
|- |
|||
| Import (invert cond) |
|||
| If disallowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
|||
|- |
|||
| Export allow Input |
|||
| Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
|||
|- |
|||
| Import allow Output |
|||
| Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
|||
|- |
|||
| Export allow Input (conditional) |
|||
| If allowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
|||
|- |
|||
| Import allow Output (conditional) |
|||
| If allowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
|||
|- |
|||
| Export allow Input (invert cond) |
|||
| If disallowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
|||
|- |
|||
| Import allow Output (invert cond) |
|||
| If disallowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
|||
|} |
|||
== Fluid Rates == |
|||
{| class="wikitable" |
|||
! Tier |
|||
! Fluid per second (L) |
|||
! Fluid per tick (L) |
|||
|- |
|||
| LV |
|||
| 640 |
|||
| 32 |
|||
|- |
|||
| MV |
|||
| 2560 |
|||
| 128 |
|||
|- |
|||
| HV |
|||
| 10240 |
|||
| 512 |
|||
|- |
|||
| EV |
|||
| 40960 |
|||
| 2048 |
|||
|- |
|||
| IV |
|||
| 163840 |
|||
| 8192 |
|||
|- |
|||
| LuV |
|||
| 327680 |
|||
| 16384 |
|||
|- |
|||
| ZPM |
|||
| 655360 |
|||
| 32768 |
|||
|- |
|||
| UV |
|||
| 1310720 |
|||
| 65536 |
|||
|} |
|||
== See also == |
== See also == |
Revision as of 17:20, 4 September 2017
The Electric Pump is a component used in the crafting of several GregTech 5 electric machines, but more importantly also functions as a cover that can be used to automate fluid extraction and insertion. A Crowbar can be used to remove the Electric Pump from the machine or pipe that it is attached to. When it is attached to a machine, it will require power. Each tier of the Electric Pump has a different speed; every tick it will attempt to move fluid, if it succeeds it will consume 1 EU per 10L of fluid. If the pump is attached to a pipe however, it is not capable of consuming power, so it still functions just the same, but does not require power.
Modes
The Electric Pump has several different operating modes. The active mode can be switched using a Screwdriver.
Mode | Description |
---|---|
Export | Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
Import | Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
Export (conditional) | If allowed by a Machine Controller, Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
Import (conditional) | If allowed by a Machine Controller, Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
Export (invert cond) | If disallowed by a Machine Controller, Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. |
Import (invert cond) | If disallowed by a Machine Controller, Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. |
Export allow Input | Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
Import allow Output | Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
Export allow Input (conditional) | If allowed by a Machine Controller, Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
Import allow Output (conditional) | If allowed by a Machine Controller, Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
Export allow Input (invert cond) | If disallowed by a Machine Controller, Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor. |
Import allow Output (invert cond) | If disallowed by a Machine Controller, Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor. |
Fluid Rates
Tier | Fluid per second (L) | Fluid per tick (L) |
---|---|---|
LV | 640 | 32 |
MV | 2560 | 128 |
HV | 10240 | 512 |
EV | 40960 | 2048 |
IV | 163840 | 8192 |
LuV | 327680 | 16384 |
ZPM | 655360 | 32768 |
UV | 1310720 | 65536 |
See also
Content in this page has been copied and possibly modified from the FTB Gamepedia Wiki at (Electric_Pump_(GregTech_5)). Such content is under the CC BY-NC-SA 3.0 License.