Electric Pump: Difference between revisions

m
link
(Created page with "Category:GT_Covers {{FTB_Attribution|url=http://ftb.gamepedia.com/Electric_Pump_(GregTech_5)|name=Electric_Pump_(GregTech_5)}}<br /> The Electric Pump is a component used...")
 
m (link)
 
(6 intermediate revisions by 3 users not shown)
Line 1:
[[Category:GT_Covers]]__FORCETOC__
<!--Ignore this Infobox stuff, WIP by Bigbass-->
{{FTB_Attribution|url=http://ftb.gamepedia.com/Electric_Pump_(GregTech_5)|name=Electric_Pump_(GregTech_5)}}<br />
<!--{{Infobox
The Electric Pump is a component used in the crafting of several [http://ftb.gamepedia.com/GregTech_5 GregTech 5] electric machines, and also functions as a cover that can be used to automate fluid extraction and insertion. A [[Crowbar]] can be used to remove the Electric Pump from the machine it is attached to.
| headerstyle = background-color:#CDDEFF;
| labelstyle = background-color:#eee;
| header1 = Electric Pump
| label5 = Label 5 | data5 = Data 5
}}-->
The Electric Pump is a component used in the crafting of several [http://ftb.gamepedia.com/GregTech_5 GregTech 5] electric machines, andbut more importantly also functions as a [[:Category:GT_Covers| cover]] that can be used to automate fluid extraction and insertion. AWhen it is attached to a machine, it will require power. Each [[Crowbartier]] canof bethe usedElectric toPump removehas thea Electricdifferent Pumpspeed; fromevery thetick machineit will attempt to move fluid, if it succeeds it will consume 1 EU per 10L of fluid. If the pump is attached to a pipe however, it is not capable of consuming power, so it still functions just the same, but does not require power.
 
A [[Crowbar]] can be used to remove an Electric Pump from a machine, cable, or pipe that it is attached to.
 
== Modes ==
The Electric Pump has several different operating modes. The active mode can be switched using a [[Screwdriver]].
 
{| class="wikitable"
TODO: Add modes table.
! Mode
! Description
|-
| Export
| Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces.
|-
| Import
| Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank.
|-
| Export (conditional)
| If allowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces.
|-
| Import (conditional)
| If allowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank.
|-
| Export (invert cond)
| If disallowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces.
|-
| Import (invert cond)
| If disallowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank.
|-
| Export allow Input
| Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor.
|-
| Import allow Output
| Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor.
|-
| Export allow Input (conditional)
| If allowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor.
|-
| Import allow Output (conditional)
| If allowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor.
|-
| Export allow Input (invert cond)
| If disallowed by a [[Machine Controller]], Fluid is taken from the attached machine's output tank, and pushed into the input tank of the machine the cover faces. Additionally, fluid can be pushed into the attached machine's input tank through the side covered by the Conveyor.
|-
| Import allow Output (invert cond)
| If disallowed by a [[Machine Controller]], Fluid is taken from the output tank of the machine the cover faces, and pushed into the attached machine's input tank. Additionally, fluid can be pulled from the attached machine's output tank through the side covered by the Conveyor.
|}
 
== Fluid Rates ==
{| class="wikitable"
! Tier
! Fluid per second (L)
! Fluid per tick (L)
|-
| LV
| 640
| 32
|-
| MV
| 2560
| 128
|-
| HV
| 10240
| 512
|-
| EV
| 40960
| 2048
|-
| IV
| 163840
| 8192
|-
| LuV
| 327680
| 16384
|-
| ZPM
| 655360
| 32768
|-
| UV
| 1310720
| 65536
|}
 
== See also ==
[[Selection Grid]]
 
{{FTB_Attribution|url=http://ftb.gamepedia.com/Electric_Pump_(GregTech_5)|name=Electric_Pump_(GregTech_5)}}<br />
4,389

edits